Search results for "Multifocal intraocular lens"

showing 10 items of 38 documents

Refractive lens exchange with the Acri. Twin asymmetric diffractive bifocal intraocular lens system

2009

PURPOSE To evaluate efficacy, safety, and predictability after refractive lens exchange (RLE) in patients who had implantation of asymmetric Acri.Twin bifocal diffractive intraocular lenses. METHODS The study comprised 130 eyes of 65 consecutive patients after RLE who had bilateral implantation of the Acri.Twin system. Eyes were divided into myopic and hyperopic groups. Binocular uncorrected distance visual acuity, best-corrected distance visual acuity (BCVA), uncorrected distance near visual acuity, and best distance-corrected near visual acuity (BCNVA) were recorded preoperatively and 6 months after surgery. RESULTS Efficacy indexes were 0.99 for myopic and 0.93 for hyperopic patients at …

AdultMaleReoperationmedicine.medical_specialtyVisual acuityDistance visual acuitygenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensRefractive lens exchangeFunctional Laterality03 medical and health sciences0302 clinical medicineLens Implantation IntraocularOphthalmologyMyopiamedicineHumansIn patientProspective StudiesAgedLenses IntraocularPhacoemulsificationbusiness.industryPresbyopiaGeneral MedicinePresbyopiaMiddle AgedMultifocal intraocular lensmedicine.diseaseeye diseasesOphthalmologyHyperopiaIntraocular lenses030221 ophthalmology & optometryFemalesense organsmedicine.symptombusiness030217 neurology & neurosurgeryEuropean Journal of Ophthalmology
researchProduct

Refractive lens exchange with an array multifocal intraocular lens.

2002

ABSTRACT PURPOSE: To prospectively evaluate safety, efficacy, predictability, stability, complications, and patient satisfaction after refractive lens exchange (clear lens extraction) followed by posterior chamber implantation of a multifocal intraocular lens (IOL). METHODS: Fifty eyes of 25 patients (mean age 51 years, range 44 to 62 years) with preoperative spherical equivalent refraction between -15.50 and +5.75 D and cylinder between 0 and 1.50 D underwent bilateral implantation of a zonal progressive multifocal IOL (Array, AMO). RESULTS: Eyes were divided into group A (n=24; myopia, average preoperative spherical equivalent refraction -7.11 ± 3.25 D (-1.75 to -15.50 D), and group B (n=…

AdultMalemedicine.medical_specialtyIntraocular pressureVisual acuitygenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensRefractive lens exchangeRefraction Ocularlaw.inventionPostoperative ComplicationsLens Implantation IntraocularlawOphthalmologymedicineMyopiaHumansProspective StudiesIntraocular PressureLenses IntraocularClear lens extractionbusiness.industryMultifocal intraocular lensMiddle AgedRefractioneye diseasesSurgeryLens (optics)OphthalmologyHyperopiaTreatment OutcomePatient SatisfactionSurgeryFemalesense organsmedicine.symptomSafetybusinessJournal of refractive surgery (Thorofare, N.J. : 1995)
researchProduct

Differences in visual performance of AcrySof ReSTOR IOL in high and low myopic eyes.

2009

PURPOSE To determine the differences in refractive and visual results obtained in eyes with high and low myopia after multifocal intraocular lens (IOL) implantation. METHODS Monocular visual acuity for distance and near, with and without distance correction, and photopic and mesopic contrast sensitivity were measured at 6 months after surgery in 152 myopic eyes implanted with the AcrySof ReSTOR Natural (SN60D3) IOL. Two groups were created: high and low myopia (76 eyes in each). RESULTS Monocular best distance-corrected visual acuity was 0.02+/-0.06 logMAR for low myopes and 0.05+/-0.09 logMAR for high myopes. Monocular best distance-corrected near visual acuity was 0.04+/-0.05 and 0.07+/-0…

AdultMalemedicine.medical_specialtyVisual acuitygenetic structuresPseudophakiaMesopic visionmedia_common.quotation_subjectProsthesis DesignRefraction OcularSeverity of Illness IndexContrast Sensitivity03 medical and health sciences0302 clinical medicineLens Implantation IntraocularOphthalmologymedicineMyopiaContrast (vision)HumansProspective Studiesmedia_commonAgedLenses IntraocularMonocularbusiness.industryGeneral MedicineMultifocal intraocular lensMiddle AgedDistance correctioneye diseasesOphthalmologyTreatment Outcome030221 ophthalmology & optometryFemalesense organsSpatial frequencymedicine.symptombusiness030217 neurology & neurosurgeryPhotopic visionEuropean journal of ophthalmology
researchProduct

Image quality with multifocal intraocular lenses and the effect of pupil size

2007

Purpose To analyze the image quality with a refractive and 2 hybrid refractive–diffractive multifocal intraocular lenses (IOLs) in vitro to determine the IOL modulation transfer function (MTF) following the EN-ISO international standard for distance and near vision and to study the IOLs' behavior with different pupil sizes. Setting Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods This study evaluated 4 IOLs: the hybrid refractive–diffractive AcrySof ReSTOR SN60D3 (Alcon) and Tecnis ZM900 (AMO), the refractive ReZoom NXG (AMO), and the monofocal AcrySof SN60WF (Alcon). The MTF was calculated from the cross-line spread function recorded with the OPAL Vector System (Image Sci…

Artificial corneaOptics and PhotonicsImage qualitymedicine.medical_treatmentIntraocular lensProsthesis DesignModels BiologicalPupilContrast SensitivityOpticsOptical transfer functionmedicineHumansImaging scienceMathematicsLenses IntraocularFourier Analysisbusiness.industryPupil sizePupilMultifocal intraocular lensSensory SystemsOphthalmologyOptometrySurgerybusinessJournal of Cataract and Refractive Surgery
researchProduct

Fractal-structured multifocal intraocular lens

2017

[EN] In this work, we present a new concept of IOL design inspired by the demonstrated properties of reduced chromatic aberration and extended depth of focus of Fractal zone plates. A detailed description of a proof of concept IOL is provided. The result was numerically characterized, and fabricated by lathe turning. The prototype was tested in vitro using dedicated optical system and software. The theoretical Point Spread Function along the optical axis, computed for several wavelengths, showed that for each wavelength, the IOL produces two main foci surrounded by numerous secondary foci that partially overlap each other for different wavelengths. The result is that both, the near focus an…

DiffractionOptical PhenomenaFocus (geometry)VisionSocial Scienceslcsh:MedicinePhysics::Optics01 natural sciences0302 clinical medicineMedicine and Health SciencesPsychologylcsh:ScienceLens (Anatomy)PhysicsMultidisciplinaryPhysicsOphthalmic ProceduresCataract SurgeryOptical LensesWavelengthFractalsOptical EquipmentPhysical SciencesEngineering and TechnologySensory PerceptionAnatomyDiffractionResearch ArticlePoint spread functionOcular AnatomyGeometryEquipmentSurgical and Invasive Medical ProceduresIn Vitro TechniquesProsthesis DesignProof of Concept Study010309 optics03 medical and health sciencesFractalOpticsOcular SystemOptical transfer function0103 physical sciencesChromatic aberrationPrototypesComputer Simulationbusiness.industrylcsh:RBiology and Life SciencesModels TheoreticalMultifocal Intraocular LensesOptical axisTechnology DevelopmentFISICA APLICADAWaves030221 ophthalmology & optometryEyeslcsh:QbusinessHeadMathematicsNeuroscience
researchProduct

Ophthalmic: Laboratorio virtual para el diseño de nuevas lentes oftálmicas

2013

This work presents a new virtual laboratory, OPHTALMIC, developed with MATLAB GUI for using in Optics and Optometry courses as a computer tool for studying the focusing properties of multifocal diffractive both on unconventional structures both periodic and aperiodic. This virtual laboratory enables students to quickly and easily analyze the influence of the different parameters of construction and find the best solution for a user.

Engineering drawingEngineeringComputer toolsbusiness.industryCantor setOptical qualitylcsh:Education (General)Multifocal intraocular lensAperiodic graphVirtual LaboratoryMATLABbusinesslcsh:L7-991computercomputer.programming_languageModelling in Science Education and Learning
researchProduct

Visual and optical performance with hybrid multifocal intraocular lenses

2010

During the past years, the wish to become independent of spectacles has been growing among cataract and presbyopic patients due to many factors, such as the increase in near visual demands, the aesthetic need for a spectacle-free image and ageing of refractive surgery patients, among others. This review assesses recently published studies that analyse visual and optical performance through different metrics of eyes implanted with multifocal intraocular lenses (IOLs), particularly hybrid IOL designs. The published evidence suggests that hybrid multifocal IOLs provide very good outcomes in a number of visual and optical performance parameters. Patients implanted with this type of IOL obtain a…

Intraocular LensesOptical PerformanceVisual acuitygenetic structuresCompensation Comparisonmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityMethodKeratomileusislaw.inventionGlareLensTratamiento médicoSensitivitylawRefractive surgeryMedicineContrast (vision)MonovisionPostoperative Periodmedia_commonVistaLenses IntraocularMultifocalsGlare (vision)Equipment DesignRefractive ErrorsLens (optics)Bilateral ImplantationApodized Diffractive IolOftalmologíamedicine.symptommedicine.medical_specialtyIn-Situ KeratomileusisRefractivemedia_common.quotation_subjectHigh-Order AberrationsContrast SensitivityOphthalmologyAberrometryClinical-OutcomesHumansRetinal StraylightDepth Perceptionbusiness.industryAberrometryMultifocal intraocular lensContrasteye diseasesOphthalmologyOptometrysense organsbusinessOptometry
researchProduct

Femtosecond laser for residual refractive error correction after refractive lens exchange with multifocal intraocular lens implantation.

2008

Purpose To assess visual and refractive outcomes of femtosecond laser for residual refractive error correction after refractive lens exchange (RLE) with multifocal intraocular lens (IOL) implantation. Design Prospective, nonrandomized, masked observational case series (self-controlled). Methods Fifty-three eyes of 31 consecutive patients were submitted to femtosecond laser surgery after RLE with multifocal IOL implantation. Patients showed an average manifest refractive error (D) of M , 0.200 ± 0.490; J 0 , −0.051 ± 0.532; and J 45 , −0.007 ± 0.371. Visual acuity (VA) was measured at distance and near vision before and six months after the surgery. Results At six months after surgery, mean …

Laser surgeryMalemedicine.medical_specialtyRefractive errorVisual acuitygenetic structuresmedicine.medical_treatmentKeratomileusis Laser In SituAcrylic ResinsVisual AcuityKeratomileusisIntraocular lensRefraction OcularPostoperative ComplicationsLens Implantation IntraocularOphthalmologymedicineMyopiaHumansProspective StudiesDioptreAgedLenses Intraocularmedicine.diagnostic_testbusiness.industryCorneal TopographyMultifocal intraocular lensMiddle AgedCorneal topographymedicine.diseasePrognosiseye diseasesOphthalmologyHyperopiaFemaleLasers Excimersense organsmedicine.symptombusinessFollow-Up StudiesAmerican journal of ophthalmology
researchProduct

Influence of trifocal intraocular lenses on standard autorefraction and aberrometer-based autorefraction.

2019

To study the agreement between manifest refraction and objective refraction measured with two autorefractor models and an aberrometer in eyes implanted with a trifocal diffractive intraocular lens (IOL).IOA Madrid Innova Ocular, Madrid, Spain.Prospective comparative cohort study.An autorefractor keratometer (KR-8800), based on a Scheiner double pinhole, and a 3-dimension wavefront topography aberrometer system (OPD-Scan III), based on the scanning-slit retinoscopy principle, were used to obtain objective refraction readings. In addition, lower-order Zernike coefficients (Z) were used to calculate objective refraction. A set of 7 different results was obtained in power vector notation (spher…

MaleCorneal Wavefront AberrationPseudophakiaMesopic visionZernike polynomialsmedicine.medical_treatmentVisual AcuityIntraocular lensRefraction OcularPupillaw.inventionsymbols.namesakeLens Implantation IntraocularlawmedicineHumansProspective StudiesRetinoscopyMathematicsAgedPhacoemulsificationmedicine.diagnostic_testKeratometerAberrometryMiddle AgedMultifocal Intraocular LensesSensory SystemsOphthalmologyAutorefractorsymbolsOptometrySurgeryFemalePhotopic visionJournal of cataract and refractive surgery
researchProduct

Working-Age Cataract Patients: Visual Results, Reading Performance, and Quality of Life with Three Diffractive Multifocal Intraocular Lenses

2013

Purpose To compare the visual outcomes, reading performance, and quality of life (QoL) of working-age cataractous patients bilaterally implanted with 3 different diffractive multifocal intraocular lenses (MIOLs). Design Two-center, randomized, prospective, double-masked study. Participants Sixty-three consecutive patients (126 eyes) seen at Ophthalmology Section, Palermo and Florence University, Italy, randomized to receive the ReSTOR SN6AD3 (Alcon Laboratories, Inc, Irvine, CA) (20 patients, group A), ReSTOR SN6AD1 (Alcon Laboratories, Inc) (21 patients, group B), or TECNIS ZMA00 (Abbott Medical Optics, Santa Ana, CA) (22 patients, group C) MIOL. Intervention Phacoemulsification. Main Outc…

MaleRefractive errorVisual acuitygenetic structuresMesopic visionmedicine.medical_treatmentMesopic VisionVisual AcuitySettore MED/42 - Igiene Generale E ApplicataLens Implantation IntraocularSickness Impact ProfileSurveys and QuestionnairesMedicineContrast (vision)Prospective StudiesProspective cohort studyOPTICAL-QUALITYmedia_commonLenses IntraocularVision BinocularOUTCOMESMiddle AgedRESTORFemalemedicine.symptomA+3.00 DPhotopic visionDIOPTER ADDITIONmedicine.medical_specialtyINSTITUTE-REFRACTIVE ERRORmedia_common.quotation_subjectMODELSProsthesis DesignCataractDouble-Blind MethodOphthalmologyCONTRAST SENSITIVITYHumansBILATERAL IMPLANTATIONPhacoemulsificationColor Visionbusiness.industrySettore MED/30 - Malattie Apparato VisivoPhacoemulsificationMultifocal intraocular lensmedicine.diseaseeye diseasesOphthalmologyVISIONINSTITUTE-REFRACTIVE ERROR; CONTRAST SENSITIVITY; BILATERAL IMPLANTATION; DIOPTER ADDITION; OPTICAL-QUALITY; A+3.00 D; VISION; RESTOR; OUTCOMES; MODELSReadingQuality of LifeOptometryMultifocal IOL diffractive Quality of lifebusinessFollow-Up Studies
researchProduct